{"id":2348,"date":"2021-01-17T11:38:30","date_gmt":"2021-01-17T11:38:30","guid":{"rendered":"http:\/\/vpxd.dc5.cz\/?p=2348"},"modified":"2022-01-21T16:55:32","modified_gmt":"2022-01-21T16:55:32","slug":"homelab-2021","status":"publish","type":"post","link":"https:\/\/vpxd.dc5.cz\/index.php\/2021\/01\/17\/homelab-2021\/","title":{"rendered":"Homelab 2021"},"content":{"rendered":"\n<p><code><div class=\"post-views content-post post-2348 entry-meta load-static\">\r\n\t\t\t\t<span class=\"post-views-icon dashicons dashicons-chart-bar\"><\/span> <span class=\"post-views-label\">Post Views:<\/span> <span class=\"post-views-count\">1,502<\/span>\r\n\t\t\t<\/div><\/code><\/p>\n\n\n\n<p>LAB for 2021 is ready. Last year new home DC building has been build. <br>Usually I run 2x vCenters, NSX-T, NSX-V, VSAN, Cloud Director, vRO, vRLI etc..<br>and a lots of linux VM&#8217;s all for testing and learning purpose. Licenses I have are from vExpert and VMUG Advantage.<\/p>\n\n\n\n<p><em>2021-01-17<\/em><\/p>\n\n\n\n<h1 class=\"wp-block-heading\">DC5<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Networking:<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Internet 500Mbit<\/li><li>Cisco 2970G<\/li><li>Zyxel GS1920<\/li><li>Mikrotik CRS 305 (4x 10Gbit)<\/li><li>Mikrotik CRS 312 (12x 10Gbit)<\/li><\/ul>\n\n\n\n<!--more-->\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Compute:<\/strong><\/h2>\n\n\n\n<p>DELL R710A<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>2x Xeon<\/li><li>192 GB RAM<\/li><li>iDRAC<\/li><li>4x NIC<\/li><\/ul>\n\n\n\n<p>DELL R710B<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>1x Xeon<\/li><li>92GB RAM<\/li><li>4x NIC<\/li><\/ul>\n\n\n\n<p>DELL R710C<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>1x Xeon<\/li><li>92GB RAM<\/li><li>4x NIC<\/li><\/ul>\n\n\n\n<p><strong>NUC1 \u2013 Test &amp; Dev<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>i3-6100U @ 2.3GHz<\/li><li>32GB RAM<\/li><li>256GB NVMe<\/li><li>500GB SATA 2,5&#8243;<\/li><li>2x 1Gbit NIC (one of them is USB TP-LINK U300)<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>VSAN Compute Cluster:<\/strong><\/h2>\n\n\n\n<p><strong>ESX2 <\/strong>(whitebox)<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Intel G4560 @ 3.5GHz<\/li><li>MB: B250M-D3H<\/li><li>64GB RAM<\/li><li>500GB NVMe Samsung 970EVO<\/li><li>1TB SSD SATA Samsung 860EVO<\/li><li>2x 256GB SSD SATA Kingston<\/li><li>4x 1Gbit NIC<\/li><li>2x 10Gbit NIC (intel X540-AT2) Base-T<\/li><\/ul>\n\n\n\n<p><strong>ESX5<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Xeon D-2123IT @ 2.2GHz<\/li><li>MB: Supermicro SYS-E300-9D-4CN8TB<\/li><li>128GB RAM<\/li><li>500GB NVMe Samsung 970EVO<\/li><li>1TB SSD SATA Samsung 860EVO<\/li><li>IPMI<\/li><li>4x 1Gbit NIC<\/li><li>2x 10Gbit NIC (intel X722) Base-T<\/li><li>2x 10Gbit NIC (intel X722) SFP+<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>ESX7<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Xeon D-2123IT @ 2.2GHz<\/li><li>MB: Supermicro SYS-E300-9D-4CN8TB<\/li><li>128GB RAM<\/li><li>500GB NVMe Samsung 970EVO<\/li><li>1TB SSD SATA Samsung 860EVO<\/li><li>IPMI<\/li><li>4x 1Gbit NIC<\/li><li>2x 10Gbit NIC (intel X722) Base-T<\/li><li>2x 10Gbit NIC (intel X722) SFP+<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Performance cluster:<\/strong><\/h2>\n\n\n\n<p><strong>ESX3<\/strong><br>IBM System x3690 X5<br>2x Xeon CPU E7- 2803 @ 1.73GHz (6core+HT)<br>256GB RAM<br>2x 1Gbit<br>2x 10Gbit<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>ESX9<\/strong><br>IBM System x3690 X5<br>2x Xeon CPU E7- 2803 @ 1.73GHz (6core+HT)<br>256GB RAM<br>2x 1Gbit<br>2x 10Gbit<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Storage:<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>NearStore<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Xeon E3-1220L @2.3GHz (4core)<\/li><li>MB: Supermicro X9SCM<\/li><li>Case: Nanoxia Deep Silence 6, Rev. B<\/li><li>32GB RAM<\/li><li>16x 2TB SATA<\/li><li>3x 3TB SATA<\/li><li>IPMI<\/li><li>2x 1Gbit NIC (82574LM + 82574L)<\/li><li>2x 10Gbit NIC (intel X540-AT2) Base-T<\/li><li>1x 10Gbit Asus<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>QNAP 653Pro<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>6x 3TB SATA<\/li><li>4x 1Gbit<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<h1 class=\"wp-block-heading\">DC 1<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Networking:<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Internet 100Mbit<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Compute:<\/strong><\/h3>\n\n\n\n<p>GOLEM &#8211; ESXi 6.5.0 \u2013 Build 10719125<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Xeon X3450 @ 2.67GHz<\/li><li>MB: S3420GP<\/li><li>Case: 1U<\/li><li>24GB RAM<\/li><li>5x 1Gbit NIC<\/li><li>2x 1TB HDD SATA<\/li><li>2x 512GB SSD SATA<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<h1 class=\"wp-block-heading\">D&amp;R Site<\/h1>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Networking:<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Internet 50Mbit<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Compute:<\/strong><\/h3>\n\n\n\n<p><strong>ESX<\/strong>2<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Xeon E3-1220L @2.3GHz (4core)<\/li><li>MB: Supermicro X9SCM<\/li><li>32GB RAM<\/li><li>2TB SATA<\/li><li>2x 1Gbit NIC (82574LM + 82574L)<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Storage:<\/strong><\/h3>\n\n\n\n<p>Synology DS210j<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>2x 3TB SATA<\/li><li>2x 1Gbit<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>LAB for 2021 is ready. Last year new home DC building has been build. Usually I run 2x vCenters, NSX-T, NSX-V, VSAN, Cloud Director, vRO, vRLI etc..and a lots of linux VM&#8217;s all for testing and learning purpose. Licenses I have are from vExpert and VMUG Advantage. 2021-01-17 DC5 Networking: Internet 500Mbit Cisco 2970G Zyxel &hellip; <a href=\"https:\/\/vpxd.dc5.cz\/index.php\/2021\/01\/17\/homelab-2021\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Homelab 2021&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[23,3,8],"tags":[],"class_list":["post-2348","post","type-post","status-publish","format-standard","hentry","category-blog","category-homelab","category-vmware"],"_links":{"self":[{"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/posts\/2348","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/comments?post=2348"}],"version-history":[{"count":5,"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/posts\/2348\/revisions"}],"predecessor-version":[{"id":2649,"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/posts\/2348\/revisions\/2649"}],"wp:attachment":[{"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/media?parent=2348"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/categories?post=2348"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vpxd.dc5.cz\/index.php\/wp-json\/wp\/v2\/tags?post=2348"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}